Today I started work on the plumbing below the tank going into the sump--the parts that the standpipes I just built will drain down into. I had a great plan for this! I decided I wanted to use union connectors immediately under my tank, so that I could disconnect my drain pipes if I need to clean or maintain them. A union connector is three pieces that look like this:

100_1694.jpg

They go together like this:

100_1697.jpg

Union connectors allow you to join your plumbing parts together in a way that allows you to unfasten them if you need to. They work pretty much like attaching a garden hose to the outside faucet; the big ring is the part you twist to join the two smaller pieces together.

The problem with these is that they are pretty big. So once I attach the top piece to my bulkhead, there's no way I'm getting the bulkhead through the hole drilled into my tank, or getting the nut that fastens the bulkhead to the tank over the union pieces.

[i should back up here a second and explain that PVC plumbing can be connected in one of two ways. There are slip connections, where you just insert one piece into another. To make slip connections watertight, you glue them together with PVC glue. The connections in my standpipes are all slip connections. There are also threaded connections, which, as you can imagine, are threaded and screw together. To make these watertight, you use teflon tape, which is not permanent.]

My drain bulkheads are slip on both the top and the bottom, so anything I attach to them (on the bottom, at least, where watertightness is important) will have to be glued in. This is fine, but if what I glue into them is larger than the bulkhead nut or the hole I need to put the bulkhead into, I have some problems. The only way to work this is to glue it in after the bulkhead is installed. There is no way to unglue the connection, so it would be permanent. Plenty of people do this, but I want my plumbing to be removable, just in case.

The plan I came up with for this problem involved this:

100_1691.jpg

I would put a small bit of PVC into my bulkhead, then attach a slip to thread adapter, and screw that into the (threaded) top of the union. (You can also get slip unions, but mine are threaded.) This is an awesome plan! The adapter is WAY smaller than the union, so it should work, right?

Nope.

I first discovered that the adapter did not fit through the hole. It almost did, but not quite. But the adapter had these little ridges on it, and I don't need those, so I took them off.

100_1684.jpg

Not the prettiest fix, but it's alright I suppose. Except it didn't work. It fit through the hole drilled in the aquarium fine. But I couldn't get the bulkhead nut over it, even after shaving off the ridges. But I am stubborn! So, after 45 minutes and coating everything including myself with about 2 inches of PVC shavings, I ended up with this:

100_1692.jpg

I basically sanded down the outside of the adapter with a dremel until the nut fit over the outside of it. It's ugly, and a bit of a kludge, but it works. (Note: I would not recommend doing this for any kind of pressure application. This part of my plumbing will be a gravity drain, so the adapter will not be under any pressure. So having thinner walls is not a big deal in this case, but it might be in other cases. I don't know for sure.)

Success! I ran to install it in my tank, so I could show the holes who's boss:

100_1698.jpg

Oooooooo. Neat! Hey, let's put the unions on too!

100_1702.jpg

Fancy. :) I decided to stop there, because that was far more complicated than I was thinking it would be. Hopefully the rest of my plumbing will be uneventful.

(A postscript: You may be wondering, "Courtney, if you're going to screw the union onto the PVC anyway, why not use skip the union and screw your plumbing straight on to the adapter?" That is a fine and astute question! I was wondering that myself, but then I realized that on the other end of the union will be some large and fairly cumbersome pipes--not the kind of thing you can go rotating 360 degrees all willy-nilly. Unfortunately, that won't work. But that's why I have unions!)

10 Comments


Recommended Comments

  • Regular Member

I really love these blog posts of yours, and look forward to new installments all the time.

How do you know so much about these plumbing things? I knew about union connectors (think water changers), but never knew that's what they were called lol.

Link to comment
  • Supporter

Great job! Your really getting to be a pro at this stuff. Every time you said "the nut" I would think you were talking about your fish for a minute. LOL

Link to comment
  • Regular Member

I really love these blog posts of yours, and look forward to new installments all the time.How do you know so much about these plumbing things? I knew about union connectors (think water changers), but never knew that's what they were called lol.

Thanks Alex! I am enjoying writing them.

Most of my plumbing knowledge is acquired by spending all of my time reading build threads on reef forums and googling inane plumbing questions. A build thread is kind of like what I'm doing here with the blog, but usually with a lot less explaining and a lot more showing off of expensive equipment. But those guys do this stuff in their sleep, pretty much, so they're good to learn from, and there are a whole heck of a lot of them.

I am admiring your handiness! Great job!

Thank you! I like working on projects like this. :)

Great job! Your really getting to be a pro at this stuff. Every time you said "the nut" I would think you were talking about your fish for a minute. LOL

I know right? I was thinking that as I was typing it. But the bulkhead nut is also a nut. It's just that that nut is not the same nut as the Nut. I was hoping the context would help.

Link to comment
  • Regular Member

Courtney, you saved me! I bought a used 120 gallon fiberglass tub that had two standpipes for overflow. Bulkheads went through the holes in the tub and in a plywood stand top, and the two drainpipes were connected to a common horizontal drain underneath. Everything was glued, so I had to cut pipes to take the bulkheads off to get the tub off the stand.

Since the holes are close to the ends of the tub, I decided to just put an elbow on the bottom of each drain pipe and drain the water off to each end.

Anyway, I had exactly the components in your third picture, except that they were 1 1/2". I would screw an elbow onto the threaded end of the adapter. Having just read your post, I checked to see if the adapter would fit through the hole and the nut. Hole, yes. Nut, no. So I followed your example and ground down the ridges. I was lucky. It slipped right through. Your good example saved me days of frustration.

Thank you!

Link to comment
  • Regular Member

Courtney, you saved me! I bought a used 120 gallon fiberglass tub that had two standpipes for overflow. Bulkheads went through the holes in the tub and in a plywood stand top, and the two drainpipes were connected to a common horizontal drain underneath. Everything was glued, so I had to cut pipes to take the bulkheads off to get the tub off the stand.Since the holes are close to the ends of the tub, I decided to just put an elbow on the bottom of each drain pipe and drain the water off to each end. Anyway, I had exactly the components in your third picture, except that they were 1 1/2". I would screw an elbow onto the threaded end of the adapter. Having just read your post, I checked to see if the adapter would fit through the hole and the nut. Hole, yes. Nut, no. So I followed your example and ground down the ridges. I was lucky. It slipped right through. Your good example saved me days of frustration.Thank you!

That is awesome to hear! My biggest goal for this blog is to help other people in similar situations. :D Was this for a big shallow tub? For some reason I am picturing a big shallow tub and I think it's because I read that you got one?

Link to comment
  • Regular Member

Yes, 2x8x1. It's set up in my screened pool enclosure and has water in it. I think I'll have fish in it tomorrow.

Link to comment
Guest
Add a comment...

×   Pasted as rich text.   Restore formatting

  Only 75 emoji are allowed.

×   Your link has been automatically embedded.   Display as a link instead

×   Your previous content has been restored.   Clear editor

×   You cannot paste images directly. Upload or insert images from URL.

×
×
  • Create New...